{"id":2883,"date":"2021-09-21T23:36:46","date_gmt":"2021-09-21T23:36:46","guid":{"rendered":"http:\/\/www.reprolam.com\/?page_id=2883"},"modified":"2021-10-13T14:21:04","modified_gmt":"2021-10-13T14:21:04","slug":"normas-utilizadas-para-la-estimacion-de-las-incertidumbres-por-los-laboratorios-de-dosimetria-externa-de-la-region","status":"publish","type":"page","link":"http:\/\/www.reprolam.com\/?page_id=2883","title":{"rendered":"Normas utilizadas para la estimaci\u00f3n de las incertidumbres por los Laboratorios de Dosimetr\u00eda Externa de la Regi\u00f3n."},"content":{"rendered":"<div id=\"pl-gb2883-6a33841a42305\"  class=\"panel-layout\" ><div id=\"pg-gb2883-6a33841a42305-0\"  class=\"panel-grid panel-has-style\" ><div class=\"panel-row-style panel-row-style-for-gb2883-6a33841a42305-0\" ><div id=\"pgc-gb2883-6a33841a42305-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-gb2883-6a33841a42305-0-0-0\" class=\"so-panel widget widget_siteorigin-panels-builder panel-first-child panel-last-child\" data-index=\"0\" ><div class=\"panel-widget-style panel-widget-style-for-gb2883-6a33841a42305-0-0-0\" ><div id=\"pl-w6166eb4e3c5f1\"  class=\"panel-layout\" ><div id=\"pg-w6166eb4e3c5f1-0\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-w6166eb4e3c5f1-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-w6166eb4e3c5f1-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2884 alignright\" src=\"http:\/\/www.reprolam.com\/wp-content\/uploads\/2021\/09\/rep17fig1.jpg\" alt=\"\" width=\"251\" height=\"284\" srcset=\"http:\/\/www.reprolam.com\/wp-content\/uploads\/2021\/09\/rep17fig1.jpg 626w, http:\/\/www.reprolam.com\/wp-content\/uploads\/2021\/09\/rep17fig1-265x300.jpg 265w\" sizes=\"(max-width: 251px) 100vw, 251px\" \/><\/p>\n<\/div>\n<\/div><\/div><\/div><div id=\"pgc-w6166eb4e3c5f1-0-1\"  class=\"panel-grid-cell\" ><div id=\"panel-w6166eb4e3c5f1-0-1-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"1\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-2885  alignnone\" src=\"http:\/\/www.reprolam.com\/wp-content\/uploads\/2021\/09\/rep17fig2-1024x322.png\" alt=\"\" width=\"461\" height=\"105\" \/><\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div id=\"pg-gb2883-6a33841a42305-1\"  class=\"panel-grid panel-has-style\" ><div class=\"panel-row-style panel-row-style-for-gb2883-6a33841a42305-1\" ><div id=\"pgc-gb2883-6a33841a42305-1-0\"  class=\"panel-grid-cell\" ><div id=\"panel-gb2883-6a33841a42305-1-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"1\" ><div class=\"panel-widget-style panel-widget-style-for-gb2883-6a33841a42305-1-0-0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t\n<table id=\"tablepress-56\" class=\"tablepress tablepress-id-56\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">LABORATORIOS<\/th><th class=\"column-2\">PA\u00cdS<\/th><th class=\"column-3\">NORMA UTILIZADA<\/th><th class=\"column-4\">FUENTES DE INCERTIDUMBRE <\/th><th class=\"column-5\">INCERTID. \u2013 NIV. DE CONF. &#8211; Hp(10)<\/th><th class=\"column-6\">INCERTID. \u2013 NIV. DE CONF.  &#8211; Hp(0.07)<\/th><th class=\"column-7\">INCERTID. \u2013 NIV. DE CONF.  &#8211; Hp(3)<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Laboratorio de Dosimetria Externa (LDE) &#8211; CPHR<\/td><td class=\"column-2\">Cuba<\/td><td class=\"column-3\">JCGM 100:2008 (GUM).<\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Variaci\u00f3n de la sensibilidad individual, Variaci\u00f3n de la lectura cero del detector, Dependencia energ\u00e9tica y angular, No linealidad de la respuesta, Desvanecimiento (fading), Errores durante la calibraci\u00f3n, Variaci\u00f3n del fondo natural<\/td><td class=\"column-5\">20%, 95%<\/td><td class=\"column-6\">25%, 95%<\/td><td class=\"column-7\">pendiente<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Sapra Landauer Servi\u00e7o de Assessoria e Prote\u00e7\u00e3o Radiol\u00f3gica<\/td><td class=\"column-2\">Brasil<\/td><td class=\"column-3\">descrito em nosso manual de qualidade <\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Variaci\u00f3n de la sensibilidad individual, Variaci\u00f3n de la lectura cero del detector, Dependencia energ\u00e9tica y angular, No linealidad de la respuesta, Desvanecimiento (fading), Variaci\u00f3n del fondo natural, Efectos debido a la exposici\u00f3n a la luz<\/td><td class=\"column-5\">0.95<\/td><td class=\"column-6\">0.95<\/td><td class=\"column-7\">0.95<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Laborat\u00f3rio de Dosimetria de F\u00f3tons &#8211; IRD<\/td><td class=\"column-2\">Brasil<\/td><td class=\"column-3\">JCGM 100:2008 (GUM).<\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Variaci\u00f3n de la sensibilidad individual, Variaci\u00f3n de la lectura cero del detector, Dependencia energ\u00e9tica y angular, No linealidad de la respuesta, Desvanecimiento (fading), Errores durante la calibraci\u00f3n, Variaci\u00f3n del fondo natural, Efectos debido a la exposici\u00f3n a la luz<\/td><td class=\"column-5\">40% del valor ~40%de la dosis, con un nivel de confianza del 95%<\/td><td class=\"column-6\">No evaluamos Hp(0.07)<\/td><td class=\"column-7\">No evaluamos Hp(3)<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">TEC-RAD<\/td><td class=\"column-2\">Brasil<\/td><td class=\"column-3\">JCGM 100:2008 (GUM).<\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Variaci\u00f3n de la sensibilidad individual, Variaci\u00f3n de la lectura cero del detector, Errores durante la calibraci\u00f3n<\/td><td class=\"column-5\">4.7<\/td><td class=\"column-6\">5.2<\/td><td class=\"column-7\">N\u00c3O SE APLICA<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Pro-Rad Consultores em Radioprote\u00e7\u00e3o<\/td><td class=\"column-2\">Brasil<\/td><td class=\"column-3\">Ainda n\u00e3o estimada<\/td><td class=\"column-4\">Ainda n\u00e3o estimada<\/td><td class=\"column-5\">Ainda n\u00e3o estimada<\/td><td class=\"column-6\">Ainda n\u00e3o estimada<\/td><td class=\"column-7\">Ainda n\u00e3o estimada<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Dosimetr\u00eda Personal S.A.S.<\/td><td class=\"column-2\">Colombia<\/td><td class=\"column-3\">ISO\/ASTM 51707: 2015 (E)<\/td><td class=\"column-4\">Errores durante la calibraci\u00f3n<\/td><td class=\"column-5\">0.05<\/td><td class=\"column-6\">0.1<\/td><td class=\"column-7\">0.05<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Laboratorio de Dosimetr\u00eda &#8211; CNSNS<\/td><td class=\"column-2\">M\u00e9xico<\/td><td class=\"column-3\">ninguna<\/td><td class=\"column-4\">Desvanecimiento (fading)<\/td><td class=\"column-5\">\u2026<\/td><td class=\"column-6\">\u2026<\/td><td class=\"column-7\">\u2026<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">MKS Protecci\u00f3n Radiol\u00f3gica<\/td><td class=\"column-2\">Argentina<\/td><td class=\"column-3\">No<\/td><td class=\"column-4\">No<\/td><td class=\"column-5\">No<\/td><td class=\"column-6\">No<\/td><td class=\"column-7\">No<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Laboratorio de Dosimetria Externa LDE, LAF-RAM<\/td><td class=\"column-2\">Nicaragua<\/td><td class=\"column-3\">JCGM 100:2008 (GUM).<\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Variaci\u00f3n de la sensibilidad individual, Variaci\u00f3n de la lectura cero del detector, Dependencia energ\u00e9tica y angular, No linealidad de la respuesta, Desvanecimiento (fading), Errores durante la calibraci\u00f3n, Variaci\u00f3n del fondo natural<\/td><td class=\"column-5\">menor al 20% para 95% de confianza<\/td><td class=\"column-6\">menor al 20% para 95% de confianza<\/td><td class=\"column-7\">menor al 20% para 95% de confianza<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Tecnof\u00edsica, S.A. de C.V.<\/td><td class=\"column-2\">M\u00e9xico<\/td><td class=\"column-3\">No hay<\/td><td class=\"column-4\">No hay<\/td><td class=\"column-5\">No hay<\/td><td class=\"column-6\">No hay<\/td><td class=\"column-7\">No hay<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Radiofisica Sanitaria &#8211; FUESMEN<\/td><td class=\"column-2\">Argentina<\/td><td class=\"column-3\">ISO\/ASTM 51707: 2015 (E)<\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Variaci\u00f3n de la sensibilidad individual, Variaci\u00f3n de la lectura cero del detector, Desvanecimiento (fading), Variaci\u00f3n del fondo natural<\/td><td class=\"column-5\">5% \/ 95<\/td><td class=\"column-6\">10% \/ 95<\/td><td class=\"column-7\">10% \/ 95<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Laboratorio de Dosimetria &#8211; ISP DE CHILE<\/td><td class=\"column-2\">Chile<\/td><td class=\"column-3\">TRAZABLE NPL303\/227 AL NETWORK DE SSDLs DEL OIEA<\/td><td class=\"column-4\">Variaci\u00f3n del fondo natural<\/td><td class=\"column-5\">1.5% ALEATORIAS Y 5.5 SISTEM\u00c1TICAS<\/td><td class=\"column-6\">NO<\/td><td class=\"column-7\">NO<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Nuclear Control Argentina<\/td><td class=\"column-2\">Argentina<\/td><td class=\"column-3\">\u2026<\/td><td class=\"column-4\">\u2026<\/td><td class=\"column-5\">\u2026<\/td><td class=\"column-6\">\u2026<\/td><td class=\"column-7\">\u2026<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Laboratorio de dosimetr\u00eda por termoluminiscencia &#8211; ARN<\/td><td class=\"column-2\">Argentina<\/td><td class=\"column-3\">JCGM 100:2008 (GUM).<\/td><td class=\"column-4\">Variaci\u00f3n de la sensibilidad individual, Errores durante la calibraci\u00f3n, Variaci\u00f3n del fondo natural<\/td><td class=\"column-5\">>= 11% (k = 2)<\/td><td class=\"column-6\">NA<\/td><td class=\"column-7\">NA<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Laboratorio de dosimetr\u00eda personal externa &#8211; CIAN<\/td><td class=\"column-2\">El Salvador<\/td><td class=\"column-3\">JCGM 100:2008 (GUM).<\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Desvanecimiento (fading)<\/td><td class=\"column-5\">Menor al 3% de la lectura con k=2<\/td><td class=\"column-6\">Menor al 3% de la lectura con k=2<\/td><td class=\"column-7\">no aplica<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Laboratorio de Dosimetr\u00eda Personal &#8211; Hospital de Esp. Carlos Andrade Mar\u00edn<\/td><td class=\"column-2\">Ecuador<\/td><td class=\"column-3\">GU\u00cdA DE SEGURIDAD No RS-G-1.3 iaea<\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Variaci\u00f3n de la sensibilidad individual, Dependencia energ\u00e9tica y angular, No linealidad de la respuesta, Errores durante la calibraci\u00f3n, Variaci\u00f3n del fondo natural<\/td><td class=\"column-5\">INCERTIDUMBRE EN EL RANGO \u201333% a +50% Y CONFIANZA 95%<\/td><td class=\"column-6\">INCERTIDUMBRE EN EL RANGO \u201333% a +50% Y CONFIANZA 95%<\/td><td class=\"column-7\">INCERTIDUMBRE EN EL RANGO \u201333% a +50% Y CONFIANZA 95%<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Laboratorio de Termoluminiscencia &#8211; CICANUM<\/td><td class=\"column-2\">Costa Rica<\/td><td class=\"column-3\">JCGM 100:2008 (GUM).<\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Variaci\u00f3n de la sensibilidad individual, Variaci\u00f3n de la lectura cero del detector, No linealidad de la respuesta, Errores durante la calibraci\u00f3n, Hay unas que no contemplan porque otras pruebas garantizan la calidad del resultado. <\/td><td class=\"column-5\">Menor al 10%<\/td><td class=\"column-6\">Menor al 10%<\/td><td class=\"column-7\">Menor al 10%<\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Laboratorio de dosimetr\u00eda personal externa &#8211; MIEM<\/td><td class=\"column-2\">Uruguay<\/td><td class=\"column-3\">JCGM 100:2008 (GUM).<\/td><td class=\"column-4\">Homogeneidad de la respuesta del detector, Variaci\u00f3n de la sensibilidad individual, Errores durante la calibraci\u00f3n<\/td><td class=\"column-5\">\u00b110%, nivel del confianza 95%<\/td><td class=\"column-6\">\u00b110% ,nivel de confianza del 95%<\/td><td class=\"column-7\">\u00b110%, nivel de confianza del 95%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-56 from cache -->\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":2381,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-templates\/page-builder.php","meta":{"footnotes":""},"_links":{"self":[{"href":"http:\/\/www.reprolam.com\/index.php?rest_route=\/wp\/v2\/pages\/2883"}],"collection":[{"href":"http:\/\/www.reprolam.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/www.reprolam.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/www.reprolam.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.reprolam.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=2883"}],"version-history":[{"count":4,"href":"http:\/\/www.reprolam.com\/index.php?rest_route=\/wp\/v2\/pages\/2883\/revisions"}],"predecessor-version":[{"id":3190,"href":"http:\/\/www.reprolam.com\/index.php?rest_route=\/wp\/v2\/pages\/2883\/revisions\/3190"}],"up":[{"embeddable":true,"href":"http:\/\/www.reprolam.com\/index.php?rest_route=\/wp\/v2\/pages\/2381"}],"wp:attachment":[{"href":"http:\/\/www.reprolam.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2883"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}